The Pro Loop NX3 loop amplifier, like all amplifiers in the NX series, is designed primarily for continuous use.
The Pro Loop NX3 loop amplifier, like all amplifiers in the NX series, is designed primarily for continuous use. The integrated switched-mode power supply and the Class-D amplifier design enable high efficiency with low waste heat and forms the basis for high reliability and operational safety.
- Automatic Gain Control (AGC) ensures a consistent level on the induction loop
- Metal Loss Correction (MLC) can be used to correct the frequency response due to metal structures in the vicinity.
| Power supply: | 100 – 240 V AC 50/60 Hz |
| Amplifier output | |
|---|---|
| Loop current max.: | 2.5 A RMS |
| Loop voltage max.: | 12 V |
| Frequency range: | 80 – 6000 Hz (± 1,5 dB) |
| Loop resistance DC: | 0,2 – 1,0 Ω |
| Outputs | |
| Loop output: | 2 pole Euroblock plug |
| Inputs | |
| Input 1: | 5-20 mV / 2 kΩ / 48 V fixed (MIC) 180 mV – 2 V / 10 kΩ (LINE) Switchable between Mic and Line Level, 3-pin Euroblock plug |
| Input 2: | 5-20 mV / 2 kΩ / 48 V switchable (MIC), 3.5 mm stereo jack socket 180 mV – 2 V / 10 kΩ (LINE), 3 pol. Euroblock Stecker |
| Input 3: | (LINE) 3.5 mm stereo jack, mono summed |
| Automatic Gain Control (AGC): voice-optimised | |
| Dynamic: | >40 dB |
| Metal Loss Correction (MLC) | |
| MLC: | 0 – 4 dB/Octave |
| Cooling | |
| Type: | fanless |
| Mechanical specifications | |
| Dimensions (H x W x D): | 32 x 167 x 95 mm |
| Weight: | 370 g |